Cell strainers are essential tools in cell biology and microbiology, used to separate cells from debris, clumps, and other unwanted materials. They come in various pore sizes, each designed to filter specific types of cells and particles. As a leading cell strainer supplier, we understand the importance of choosing the right strainer for your specific needs. In this blog post, we will explore the different types of cells that can be filtered using a cell strainer and provide guidance on selecting the appropriate pore size.
Understanding Cell Strainers
Cell strainers are typically made of nylon or polyester mesh, which is supported by a rigid plastic frame. The mesh is available in a range of pore sizes, from as small as 20 µm to as large as 400 µm. The pore size determines the size of particles that can pass through the strainer, allowing for the separation of cells based on their size.
When choosing a cell strainer, it is important to consider the size of the cells you are working with. Cells can vary greatly in size, from small bacteria and yeast to large mammalian cells. By selecting a strainer with the appropriate pore size, you can ensure that the cells of interest pass through the strainer while larger particles, such as debris and clumps, are retained.
Types of Cells Filtered by Cell Strainers
Bacteria and Yeast
Bacteria and yeast are some of the smallest cells, typically ranging in size from 0.5 to 5 µm. For filtering bacteria and yeast, a cell strainer with a pore size of 20 to 40 µm is usually sufficient. These small pore sizes allow the bacteria and yeast to pass through the strainer while retaining larger particles, such as cell debris and aggregates. For example, our 40um Cell Strainer is ideal for separating bacteria and yeast from larger contaminants.


Blood Cells
Blood contains a variety of cell types, including red blood cells (RBCs), white blood cells (WBCs), and platelets. RBCs are the smallest blood cells, with a diameter of approximately 7-8 µm, while WBCs are larger, ranging from 10 to 20 µm in size. Platelets are the smallest, with a diameter of 2-4 µm.
To filter blood cells, a cell strainer with a pore size of 70 to 100 µm is commonly used. This pore size allows the majority of blood cells to pass through while retaining larger clumps and debris. Our 70um Cell Strainer and 100um Cell Strainer are suitable for this application, ensuring a clean and homogeneous cell suspension.
Mammalian Cells
Mammalian cells, such as fibroblasts, epithelial cells, and immune cells, are generally larger than bacteria and blood cells, with sizes ranging from 10 to 100 µm. For filtering mammalian cells, a cell strainer with a pore size of 40 to 100 µm is typically recommended.
Smaller pore sizes, such as 40 µm, are suitable for filtering single cells and removing small aggregates, while larger pore sizes, such as 70 or 100 µm, can be used to separate cells from larger debris and clumps. The choice of pore size depends on the specific cell type and the degree of cell aggregation.
Stem Cells
Stem cells are undifferentiated cells that have the potential to develop into various cell types. They are often used in research and regenerative medicine. Stem cells can vary in size, but they are generally in the range of 10 to 20 µm.
A cell strainer with a pore size of 40 to 70 µm is commonly used to filter stem cells. This allows the stem cells to pass through while removing larger particles and aggregates. Our 40um Cell Strainer and 70um Cell Strainer are well-suited for this application, ensuring the purity and viability of the stem cell population.
Factors Affecting Cell Filtration
In addition to the pore size, several other factors can affect the efficiency of cell filtration using a cell strainer. These factors include the cell concentration, the viscosity of the sample, and the presence of debris and aggregates.
- Cell Concentration: High cell concentrations can lead to clogging of the strainer, reducing the efficiency of filtration. It is recommended to dilute the cell suspension to an appropriate concentration before filtration.
- Sample Viscosity: Samples with high viscosity, such as those containing mucus or extracellular matrix, can also cause clogging. In such cases, it may be necessary to pre - treat the sample to reduce its viscosity, for example, by adding enzymes or using gentle agitation.
- Debris and Aggregates: The presence of large debris and aggregates in the sample can block the pores of the strainer. It is advisable to remove as much debris as possible before filtration, for example, by centrifugation or sedimentation.
Selecting the Right Cell Strainer
When selecting a cell strainer, it is important to consider the following factors:
- Pore Size: As discussed above, the pore size should be chosen based on the size of the cells you are working with.
- Material: Cell strainers are available in different materials, such as nylon and polyester. Nylon strainers are more flexible and have a lower protein binding capacity, while polyester strainers are more rigid and have a higher chemical resistance.
- Sterility: For cell culture applications, it is essential to use sterile cell strainers to prevent contamination. We offer a range of sterile cell strainers that are suitable for a variety of applications.
- Capacity: The capacity of the cell strainer refers to the volume of the sample it can hold. Choose a strainer with an appropriate capacity based on the volume of your cell suspension.
Conclusion
Cell strainers are valuable tools for separating cells from debris and aggregates in a variety of biological applications. By understanding the different types of cells that can be filtered and the factors affecting cell filtration, you can choose the right cell strainer for your specific needs.
As a trusted cell strainer supplier, we offer a wide range of cell strainers with different pore sizes, materials, and capacities. Our high - quality cell strainers are designed to provide efficient and reliable cell filtration. If you are interested in purchasing cell strainers or have any questions about our products, please feel free to contact us for further discussion and procurement negotiation. We look forward to serving you and meeting your cell filtration requirements.
References
- Alberts, B., Johnson, A., Lewis, J., Raff, M., Roberts, K., & Walter, P. (2002). Molecular Biology of the Cell. Garland Science.
- Pollard, T. D., & Earnshaw, W. C. (2004). Cell Biology. Saunders.
- Freshney, R. I. (2010). Culture of Animal Cells: A Manual of Basic Technique and Specialized Applications. Wiley - Liss.